Model | 50A | 60A | 70A | ||
Charging Mode | MPPT Automatic Maximum Power Point Tracking | ||||
Charging Method | Three stages : Constant Current ( MPPT), Balanced Charging, Floating Charge | ||||
System Type | 12 V/ 24 V/ 48 V | Automatic Identification/ Manual Setting | |||
System Identification Voltage Range | 12 V System | DC 9 V- DC 15 V | |||
24 V System | DC 18 V- DC 30 V | ||||
48 V System | DC 36 V- DC 60 V | ||||
Soft Start Time | 12 V/ 24 V/ 48 V | ≤10 s | |||
Dynamic Response Recovery Time | 12 V/ 24 V/ 48 V | ≤500 us | |||
Static Power | 12 V/ 24 V/ 48 V | ≤2 W | |||
Machine Efficiency | 12 V/ 24 V/ 48 V | ≥96 . 5 % | |||
PV Module Utilization | 12 V/ 24 V/ 48 V | ≤99 . 97 % | |||
Input Characteristics | Input Characteristics Detailed Info as bellow | ||||
MPPT Operating Voltage Range | 12 V System | DC 18 V- DC 150 V | |||
24 V System | DC 34 V- DC 150 V | ||||
48 V System | DC 65 V- DC 150 V | ||||
Input Low Voltage Protection Point | 12 V System | DC 16 V | |||
24 V System | DC 30 V | ||||
48 V System | DC 60 V | ||||
Input Low Voltage Recovery Point | 12 V System | DC 18 V | |||
24 V System | DC 34 V | ||||
36 V System | DC 65 V | ||||
Limit Input Voltage | 12 V/ 24 V/ 48 V | DC 160 V | |||
Over voltage Protection | 12 V/ 24 V/ 48 V | DC 150 V | |||
Over voltage Recovery | 12 V/ 24 V/ 48 V | DC 145 V | |||
Output Characteristics | Output Characteristics Datasheet as bellow (12 V/ 24 V/ 48 V) | ||||
Optional Battery Type (Default is lead - acid maintenance- free battery) | Lead- acid maintenance- free Battery, G e l Battery, Liquid Battery, Lithium Battery ( Can also be customized for other types of battery) |